UF15p23 AC230V 35/30W Terminal or Lead Wire Power Supply Medical Equipment AC Cooling Fan Ventilation Fan

Product Details
Customization: Available
Material: Aluminum
Usage: for Experiment, for Air Conditioner, for Manufacture, for Refrigerate
Still deciding? Get samples of US$ 30/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • UF15p23 AC230V 35/30W Terminal or Lead Wire Power Supply Medical Equipment AC Cooling Fan Ventilation Fan
  • UF15p23 AC230V 35/30W Terminal or Lead Wire Power Supply Medical Equipment AC Cooling Fan Ventilation Fan
  • UF15p23 AC230V 35/30W Terminal or Lead Wire Power Supply Medical Equipment AC Cooling Fan Ventilation Fan
  • UF15p23 AC230V 35/30W Terminal or Lead Wire Power Supply Medical Equipment AC Cooling Fan Ventilation Fan
  • UF15p23 AC230V 35/30W Terminal or Lead Wire Power Supply Medical Equipment AC Cooling Fan Ventilation Fan
  • UF15p23 AC230V 35/30W Terminal or Lead Wire Power Supply Medical Equipment AC Cooling Fan Ventilation Fan
Find Similar Products
  • Overview
  • Product Parameters
  • Detailed Photos
  • Application industry
  • Remarks
  • Company Profile
  • Certifications
  • Tips
  • Feedback from our clients
Overview

Basic Info.

Model NO.
UF-15P23
Pressure
Medium Pressure
Certification
RoHS, CE
Model
UF15p23bwh
Size
172*150*51mm
Rated Voltage
AC230V
Current
0.23/0.18A
Input Power
35/30W
Transport Package
Carton Packing
Specification
388*327*400mm/box
Trademark
FULLTECH
Origin
Taiwan, China
HS Code
8414599050
Production Capacity
500000pieces/Year

Packaging & Delivery

Package Size
35.00cm * 35.00cm * 20.00cm
Package Gross Weight
2.000kg

Product Description

 
 

Product Parameters

 
Model    Spec. Part Number Terminal Lead Wire Bearing System Rated Voltage AC Freq Current Input Power Speed Air Flow Air Flow Static Pressure Noise Level Weight
(AC V) (HZ) (A) (W) (RPM) (CFM) (m³/Min) (Inch-H2O) (dB-A) (kg)
UF-15P23BTH Terminal ball 230 50/60 0.23/0.18 35/30 2750/3100 170/195 4.8/5.5 0.42/0.38 50/55 0.9
UF-15P11BTH Terminal ball 115 50/60 0.43/0.36 35/30 2750/3100 170/195 4.8/5.5 0.42/0.38 50/55 0.9
                         
 Above Specification is only for reference, please contact us for more details.

Other models:

  UF15PC23-H UF15PC23-L UF15PE23 UF15KC23-H UF15KCR10-H UF15KCR20-H UF15KC23-H UF15KM10-H UF15KM11-H UF15KM20-H 
UF15KM23-H UF15KMR10-H UF15KMR20-H UF15KMR23-H UF15KE23-H UF15KMRE23-H UF15AC10-H UF15AC20-H UF15AC23-H UF15AC11-L
 UF15AC23-L UF15A23-H UF12AR10-H UF12AR11-H UF12AR20-H UF12AR23-H UF12AR11-M UF12AR23-M UF12AR23-L UF12A10-H 
UF12A20-H UF12A23-H UF12A11-M UF12A23-M UF12A23-L UF12AE11 UF12AE23 UF12AM10-H UF12AM20-H UF12AM23-H UF12BR23-H 
UF12B10-H UF12B20-H UF12B23-H UF UF12B23-L UF92AM10-H UF92AM20-H UF92AM23-H UF92B10-H UF92B20-H UF92B23-H 
UF92B23-L UF80B10-H UF80B20-H UF80B23-H UF80B23-L UF80A10-H UF80A20-H UF80A23-H UF80A23-L UF60D10-H UF60D20-H
 UF60D23-H UF1523-H UF16FC10-H UF16FC11-H UF16FC20-H UF16FC23-H UF17P23-H UF17P23-L UF18JC10-H UF18JC23-H 
UF25GC10-H UF25GC23-H UF25GCE23-H 

UF15p23 AC230V 35/30W Terminal or Lead Wire Power Supply Medical Equipment AC Cooling Fan Ventilation Fan

Detailed Photos

UF15p23 AC230V 35/30W Terminal or Lead Wire Power Supply Medical Equipment AC Cooling Fan Ventilation Fan
UF15p23 AC230V 35/30W Terminal or Lead Wire Power Supply Medical Equipment AC Cooling Fan Ventilation Fan

UF15p23 AC230V 35/30W Terminal or Lead Wire Power Supply Medical Equipment AC Cooling Fan Ventilation Fan

Application industry


Axial fans are used for stable cooling in many different applications and locations.
If the temperature of a device increases, the lives of its internal parts will be reduced and malfunctions could result.
Particularly devices and parts that generate heat are greatly affected by heat.
Device internal cooling and fan selection are extremely important to long-term usage of the parts inside devices.
UF15p23 AC230V 35/30W Terminal or Lead Wire Power Supply Medical Equipment AC Cooling Fan Ventilation Fan

Remarks

 

Packaging Details        Carton Case or according to your demands
Port                                Shenzhen/hongkong
Lead time                      About 1 weeks after payment confirmed or according to order quantity
After sales service       Warranty is 12 months from shipping date
Packaging picture Example 

UF15p23 AC230V 35/30W Terminal or Lead Wire Power Supply Medical Equipment AC Cooling Fan Ventilation Fan

Company Profile

UF15p23 AC230V 35/30W Terminal or Lead Wire Power Supply Medical Equipment AC Cooling Fan Ventilation Fan

 

UF15p23 AC230V 35/30W Terminal or Lead Wire Power Supply Medical Equipment AC Cooling Fan Ventilation Fan

 

UF15p23 AC230V 35/30W Terminal or Lead Wire Power Supply Medical Equipment AC Cooling Fan Ventilation Fan

UF15p23 AC230V 35/30W Terminal or Lead Wire Power Supply Medical Equipment AC Cooling Fan Ventilation Fan

Certifications

 

UF15p23 AC230V 35/30W Terminal or Lead Wire Power Supply Medical Equipment AC Cooling Fan Ventilation Fan
 

 

Tips


1. When the cooling fan is running, sometimes there is a "da da" collision sound, and sometimes there is no sound.

The reason may be that the dense and messy data cables and power cables in the cooling fan have touched the fan blades of the fan, causing the cooling fan to make abnormal noises when it rotates.

Solution: Use rubber bands, adhesive tape, etc. to bundle the data and power cables inside the half fan, and avoid passing over the cooling fan.

2. The cooling fan was used normally in the early stage, but recently it was suddenly found that the fan automatically moved to a fixed position.

The reason may be that the fastener of the radiator fails, and the fan is displaced due to the resonance phenomenon caused by the rotation of the fan.

Solution: Replace with a new buckle.

3. The cooling fan suddenly makes a loud noise when it is in use, even louder than the sound made by the chassis power supply.

The reason may be that too much dust has accumulated on the surface of the cooling fan and the gaps in the radiator, and the motor lubricating oil of the fan has completely dried up, which causes a motor-like roar.

Solution: We can wipe the cooling fan with soft paper, and use a medical swab to wipe the gaps, then open the plastic sticker off the fan, and drop one to two drops of ordinary sewing machine oil into the movement.

4. If the cooling fan is used for less than a week, there will be excessive noise and poor rotation, but it will return to normal after a period of time.

The reason may be that the indoor temperature where the cooling fan is located is low, which causes the lubricating oil on the rotating bearing to fail.

Solution: Add antifreeze lubricating oil to the cooling fan, pay attention to the temperature of the use environment, and pay attention to its maintenance.

 

Feedback from our clients

UF15p23 AC230V 35/30W Terminal or Lead Wire Power Supply Medical Equipment AC Cooling Fan Ventilation Fan

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier