Luckyxin 280mm 230V Radial Bearings Brushless Ec Metal Fan Low Noise HVAC Blower Exhaustg Fan Backward Centrifugal Fan

Product Details
Customization: Available
Material: Plastic
Usage: for Experiment, for Air Conditioner
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

  • Luckyxin 280mm 230V Radial Bearings Brushless Ec Metal Fan Low Noise HVAC Blower Exhaustg Fan Backward Centrifugal Fan
  • Luckyxin 280mm 230V Radial Bearings Brushless Ec Metal Fan Low Noise HVAC Blower Exhaustg Fan Backward Centrifugal Fan
  • Luckyxin 280mm 230V Radial Bearings Brushless Ec Metal Fan Low Noise HVAC Blower Exhaustg Fan Backward Centrifugal Fan
  • Luckyxin 280mm 230V Radial Bearings Brushless Ec Metal Fan Low Noise HVAC Blower Exhaustg Fan Backward Centrifugal Fan
  • Luckyxin 280mm 230V Radial Bearings Brushless Ec Metal Fan Low Noise HVAC Blower Exhaustg Fan Backward Centrifugal Fan
  • Luckyxin 280mm 230V Radial Bearings Brushless Ec Metal Fan Low Noise HVAC Blower Exhaustg Fan Backward Centrifugal Fan
Find Similar Products
  • Overview
  • Product Parameters
  • Detailed Photos
  • Application industry
  • Remarks
  • Company Profile
  • Certifications
  • Tips
  • Feedback from our clients
Overview

Basic Info.

Model NO.
DL280B22H
Flow Direction
Centrifugal
Pressure
Medium Pressure
Certification
RoHS, ISO, CE
Size
280X164mm
Rated Voltage
AC110V 220V
Input Power
150W
Air Flow
1060cfm
Transport Package
Carton Packing
Specification
280mm
Trademark
luckyxin
Origin
China
HS Code
8414599050
Production Capacity
1000000pieces/Year

Product Description

 
 

Product Parameters

 
Speed 1900RPM Frame PBT
Airflow 1060CFM Impeller PBT
Pressure 48mmAq Insulation Class A
Nosie 77dBA Bearing System 2 Ball,Longlife Sleeve, FDB
Voltage 110v-220v Operation Temperature -10ºC-70ºC
Motor AC external rotor motor    

Our company specializes in the production of cooling fans. If you have other selection requirements, please contact us:

1. 280mm 225W Waterproof Radial Fans Ec Backward Centrifugal Fan for Air Conditioning  

2. 280mm High Quality and Low-noise 230V 380V AC Backward Centrifugal Fan 2500RPM 1700m ³/h  

3. Hot Selling Wholesale HVAC Industrial 280mm*135mm Backward Centrifugal Fan Radial Impeller High Pressure Centrifugal Fan  

4. AC 280mm Radical Backward Centrifugal Fan Industrial Centrifugal Exhaust Trade Blower Fan  

5. 280mm 2 Poles Ac Backward Curved Centrifugal Fans Aluminum Metal Blade Centrifugal Ventilation Fan for Duct air Purifier  

6. AC 280mm Aluminum Impeller Backward Curved Blade Centrifugal Fan Cooling Fan

Luckyxin 280mm 230V Radial Bearings Brushless Ec Metal Fan Low Noise HVAC Blower Exhaustg Fan Backward Centrifugal Fan

Detailed Photos

Luckyxin 280mm 230V Radial Bearings Brushless Ec Metal Fan Low Noise HVAC Blower Exhaustg Fan Backward Centrifugal Fan
Luckyxin 280mm 230V Radial Bearings Brushless Ec Metal Fan Low Noise HVAC Blower Exhaustg Fan Backward Centrifugal Fan

Luckyxin 280mm 230V Radial Bearings Brushless Ec Metal Fan Low Noise HVAC Blower Exhaustg Fan Backward Centrifugal Fan

Application industry


Axial fans are used for stable cooling in many different applications and locations.
If the temperature of a device increases, the lives of its internal parts will be reduced and malfunctions could result.
Particularly devices and parts that generate heat are greatly affected by heat.
Device internal cooling and fan selection are extremely important to long-term usage of the parts inside devices.
Luckyxin 280mm 230V Radial Bearings Brushless Ec Metal Fan Low Noise HVAC Blower Exhaustg Fan Backward Centrifugal Fan

Remarks

 

Packaging Details        Carton Case or according to your demands
Port                                Shenzhen/hongkong
Lead time                      About 1 weeks after payment confirmed or according to order quantity
After sales service       Warranty is 12 months from shipping date
Packaging picture Example 

Luckyxin 280mm 230V Radial Bearings Brushless Ec Metal Fan Low Noise HVAC Blower Exhaustg Fan Backward Centrifugal Fan

Company Profile

Luckyxin 280mm 230V Radial Bearings Brushless Ec Metal Fan Low Noise HVAC Blower Exhaustg Fan Backward Centrifugal Fan

 

Luckyxin 280mm 230V Radial Bearings Brushless Ec Metal Fan Low Noise HVAC Blower Exhaustg Fan Backward Centrifugal Fan

 

Luckyxin 280mm 230V Radial Bearings Brushless Ec Metal Fan Low Noise HVAC Blower Exhaustg Fan Backward Centrifugal Fan

Luckyxin 280mm 230V Radial Bearings Brushless Ec Metal Fan Low Noise HVAC Blower Exhaustg Fan Backward Centrifugal Fan

Certifications

 

Luckyxin 280mm 230V Radial Bearings Brushless Ec Metal Fan Low Noise HVAC Blower Exhaustg Fan Backward Centrifugal Fan
 

 

Tips


1. When the cooling fan is running, sometimes there is a "da da" collision sound, and sometimes there is no sound.

The reason may be that the dense and messy data cables and power cables in the cooling fan have touched the fan blades of the fan, causing the cooling fan to make abnormal noises when it rotates.

Solution: Use rubber bands, adhesive tape, etc. to bundle the data and power cables inside the half fan, and avoid passing over the cooling fan.

2. The cooling fan was used normally in the early stage, but recently it was suddenly found that the fan automatically moved to a fixed position.

The reason may be that the fastener of the radiator fails, and the fan is displaced due to the resonance phenomenon caused by the rotation of the fan.

Solution: Replace with a new buckle.

3. The cooling fan suddenly makes a loud noise when it is in use, even louder than the sound made by the chassis power supply.

The reason may be that too much dust has accumulated on the surface of the cooling fan and the gaps in the radiator, and the motor lubricating oil of the fan has completely dried up, which causes a motor-like roar.

Solution: We can wipe the cooling fan with soft paper, and use a medical swab to wipe the gaps, then open the plastic sticker off the fan, and drop one to two drops of ordinary sewing machine oil into the movement.

4. If the cooling fan is used for less than a week, there will be excessive noise and poor rotation, but it will return to normal after a period of time.

The reason may be that the indoor temperature where the cooling fan is located is low, which causes the lubricating oil on the rotating bearing to fail.

Solution: Add antifreeze lubricating oil to the cooling fan, pay attention to the temperature of the use environment, and pay attention to its maintenance.

 

Feedback from our clients

Luckyxin 280mm 230V Radial Bearings Brushless Ec Metal Fan Low Noise HVAC Blower Exhaustg Fan Backward Centrifugal Fan







 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
People who viewed this also viewed