Sunon Original PE60251b1-000c-A99 DC12V DC24V 7600rpm Auto Restart 60X60X25mm 6025 24 Volt DC Fan Cooling DC Brushless

Still deciding? Get samples of $ !
Request Sample
Product Details
Customization: Available
Material: Plastic
Usage: for Experiment, for Air Conditioner
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

  • Sunon Original PE60251b1-000c-A99 DC12V DC24V 7600rpm Auto Restart 60X60X25mm 6025 24 Volt DC Fan Cooling DC Brushless
  • Sunon Original PE60251b1-000c-A99 DC12V DC24V 7600rpm Auto Restart 60X60X25mm 6025 24 Volt DC Fan Cooling DC Brushless
  • Sunon Original PE60251b1-000c-A99 DC12V DC24V 7600rpm Auto Restart 60X60X25mm 6025 24 Volt DC Fan Cooling DC Brushless
  • Sunon Original PE60251b1-000c-A99 DC12V DC24V 7600rpm Auto Restart 60X60X25mm 6025 24 Volt DC Fan Cooling DC Brushless
  • Sunon Original PE60251b1-000c-A99 DC12V DC24V 7600rpm Auto Restart 60X60X25mm 6025 24 Volt DC Fan Cooling DC Brushless
  • Sunon Original PE60251b1-000c-A99 DC12V DC24V 7600rpm Auto Restart 60X60X25mm 6025 24 Volt DC Fan Cooling DC Brushless
Find Similar Products
  • Overview
  • Product Parameters
  • Detailed Photos
  • Application industry
  • Remarks
  • Company Profile
  • Certifications
  • Tips
  • Feedback from our clients
Overview

Basic Info.

Model NO.
PE60251B1-000C-A99
Flow Direction
Axial Flow
Pressure
Low Pressure
Certification
RoHS, ISO, CE
Size
60X60X25mm
Rated Voltage
DC12V DC24V
Current
0.37A
Input Power
4.44W
Transport Package
Carton Packing
Specification
6cm
Trademark
sunon
Origin
China
HS Code
8414599050
Production Capacity
1000000pieces/Year

Product Description

 
 

Product Parameters

 
Speed 5600-7600RPM Frame Aluminum
Airflow 29-40CFM Impeller PBT
Pressure 0.36-0.64InH2O Insulation Class A
Nosie 38-46DB Bearing System 2 Ball,Longlife Sleeve, FDB
Voltage DC12v DC24V Operation Temperature -10ºC-70ºC
Motor DC brushless motor    

Our company specializes in the production of cooling fans. If you have other selection requirements, please contact us

PE60251BX-000C-A99
PE60251B1-000C-A99
PE60251B2-000C-A99
PE60251B3-000C-A99
PE60252BX-000C-A99
PE60252B1-000C-A99
PE60252B2-000C-A99
PE60252B3-000C-A99
PE60201BX-000C-A99
PE60201B1-000C-A99
PE60201B2-000C-A99
PE60201B3-000C-A99
PE60201B4-000C-A99

Detailed Photos

Sunon Original PE60251b1-000c-A99 DC12V DC24V 7600rpm Auto Restart 60X60X25mm 6025 24 Volt DC Fan Cooling DC Brushless
Sunon Original PE60251b1-000c-A99 DC12V DC24V 7600rpm Auto Restart 60X60X25mm 6025 24 Volt DC Fan Cooling DC Brushless

Sunon Original PE60251b1-000c-A99 DC12V DC24V 7600rpm Auto Restart 60X60X25mm 6025 24 Volt DC Fan Cooling DC Brushless

Sunon Original PE60251b1-000c-A99 DC12V DC24V 7600rpm Auto Restart 60X60X25mm 6025 24 Volt DC Fan Cooling DC Brushless

Application industry


Axial fans are used for stable cooling in many different applications and locations.
If the temperature of a device increases, the lives of its internal parts will be reduced and malfunctions could result.
Particularly devices and parts that generate heat are greatly affected by heat.
Device internal cooling and fan selection are extremely important to long-term usage of the parts inside devices.
Sunon Original PE60251b1-000c-A99 DC12V DC24V 7600rpm Auto Restart 60X60X25mm 6025 24 Volt DC Fan Cooling DC Brushless

Remarks

 

Packaging Details        Carton Case or according to your demands
Port                                Shenzhen/hongkong
Lead time                      About 1 weeks after payment confirmed or according to order quantity
After sales service       Warranty is 12 months from shipping date
Packaging picture Example 

Sunon Original PE60251b1-000c-A99 DC12V DC24V 7600rpm Auto Restart 60X60X25mm 6025 24 Volt DC Fan Cooling DC Brushless

Company Profile

Sunon Original PE60251b1-000c-A99 DC12V DC24V 7600rpm Auto Restart 60X60X25mm 6025 24 Volt DC Fan Cooling DC Brushless

 

Sunon Original PE60251b1-000c-A99 DC12V DC24V 7600rpm Auto Restart 60X60X25mm 6025 24 Volt DC Fan Cooling DC Brushless

 

Sunon Original PE60251b1-000c-A99 DC12V DC24V 7600rpm Auto Restart 60X60X25mm 6025 24 Volt DC Fan Cooling DC Brushless

Sunon Original PE60251b1-000c-A99 DC12V DC24V 7600rpm Auto Restart 60X60X25mm 6025 24 Volt DC Fan Cooling DC Brushless

Certifications

 

Sunon Original PE60251b1-000c-A99 DC12V DC24V 7600rpm Auto Restart 60X60X25mm 6025 24 Volt DC Fan Cooling DC Brushless
 

 

Tips


1. When the cooling fan is running, sometimes there is a "da da" collision sound, and sometimes there is no sound.

The reason may be that the dense and messy data cables and power cables in the cooling fan have touched the fan blades of the fan, causing the cooling fan to make abnormal noises when it rotates.

Solution: Use rubber bands, adhesive tape, etc. to bundle the data and power cables inside the half fan, and avoid passing over the cooling fan.

2. The cooling fan was used normally in the early stage, but recently it was suddenly found that the fan automatically moved to a fixed position.

The reason may be that the fastener of the radiator fails, and the fan is displaced due to the resonance phenomenon caused by the rotation of the fan.

Solution: Replace with a new buckle.

3. The cooling fan suddenly makes a loud noise when it is in use, even louder than the sound made by the chassis power supply.

The reason may be that too much dust has accumulated on the surface of the cooling fan and the gaps in the radiator, and the motor lubricating oil of the fan has completely dried up, which causes a motor-like roar.

Solution: We can wipe the cooling fan with soft paper, and use a medical swab to wipe the gaps, then open the plastic sticker off the fan, and drop one to two drops of ordinary sewing machine oil into the movement.

4. If the cooling fan is used for less than a week, there will be excessive noise and poor rotation, but it will return to normal after a period of time.

The reason may be that the indoor temperature where the cooling fan is located is low, which causes the lubricating oil on the rotating bearing to fail.

Solution: Add antifreeze lubricating oil to the cooling fan, pay attention to the temperature of the use environment, and pay attention to its maintenance.

 

Feedback from our clients

Sunon Original PE60251b1-000c-A99 DC12V DC24V 7600rpm Auto Restart 60X60X25mm 6025 24 Volt DC Fan Cooling DC Brushless







 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now