AC 110V 220V 380V 60mm-280mm High Airflow Axial Flow Industrial Fan for Ventilation Exhaust Cooling System

Product Details
Customization: Available
Material: Aluminum
Usage: for Experiment, for Air Conditioner, for Manufacture
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

  • AC 110V 220V 380V 60mm-280mm High Airflow Axial Flow Industrial Fan for Ventilation Exhaust Cooling System
  • AC 110V 220V 380V 60mm-280mm High Airflow Axial Flow Industrial Fan for Ventilation Exhaust Cooling System
  • AC 110V 220V 380V 60mm-280mm High Airflow Axial Flow Industrial Fan for Ventilation Exhaust Cooling System
  • AC 110V 220V 380V 60mm-280mm High Airflow Axial Flow Industrial Fan for Ventilation Exhaust Cooling System
  • AC 110V 220V 380V 60mm-280mm High Airflow Axial Flow Industrial Fan for Ventilation Exhaust Cooling System
  • AC 110V 220V 380V 60mm-280mm High Airflow Axial Flow Industrial Fan for Ventilation Exhaust Cooling System
Find Similar Products
  • Overview
  • Product Parameters
  • Detailed Photos
  • Application industry
  • Remarks
  • Company Profile
  • Certifications
  • Tips
  • Feedback from our clients
Overview

Basic Info.

Flow Direction
Axial Flow
Pressure
Medium Pressure
Certification
RoHS, CE
Model
60/80/90/120/150/180/200/250mm
Size
120*120*38mm
Rated Voltage
AC230V
Current
0.14/0.12A
Input Power
22/21W
Transport Package
Carton Packing
Specification
120*120*38mm
Trademark
luckyxin
Origin
Taiwan, China
HS Code
8414599050
Production Capacity
500000pieces/Year

Product Description

 
 

Product Parameters

  
Model    Spec. Part Number Terminal Lead Wire Bearing System Rated Voltage AC Freq Current Input Power Speed Air Flow Static Pressure Noise Level Weight
(AC V) (HZ) (A) (W) (RPM) (CFM) (Inch-H2O) (dB-A) (kg)
DP200A 2123 XBT. GN Terminal ball 230 50/60 0.14/0.12 22/21 2850/3150 97/117 0.34/0.39 45/50 0.55
DP200A 2123 XST. GN Terminal ball 230 50/60 0.14/0.12 22/21 2850/3150 97/117 0.34/0.39 45/50 0.55
                       

for ebmpapst Cooling Fan 4650N, All Metal High Temperature Resistant Axial Cooling Fan 2-Pin 120x120x38mm AC 230V 50/60Hz

 

AXIAL 1238, ac Fan, 120V AC 120mm x 38mm High Speed, UL-Certified for DIY Cooling Ventilation Exhaust Projects

 

for ebm-papst W2E142-BB01-01 7056ES Cooling Fan,230V 50/60Hz 27/28W 172×150×38mm Metal high Temperature Resistant Fan

 

Computer Fan with AC Plug, 120mm Variable Speed Axial Muffin PC Fan with Controller 120V 110V 220V

 

AC Axial Fan 17251, 110V 120V AC 172mm x 150mm x 51mm Dual Ball Bearing High Speed for DIY

 

for ebmpapst 4600N-466 Axial Fan,115V 20W 106CFM Industrial Cooling Fan All-Metal Heat-Resistant Cooling Fan 4600N-466

 

DV4600-492 Cabinet Compact Cooling Fan 115V 18/19W 220/240mA 12CM 120×120×38mm 3100RPM 2-Wire Axial Flow Fan

 

AXIAL 12038Fan, 120V AC 120mm x 38mm Low Speed, UL-Certified for DIY Cooling Ventilation Exhaust Projects




 

 

Detailed Photos

AC 110V 220V 380V 60mm-280mm High Airflow Axial Flow Industrial Fan for Ventilation Exhaust Cooling System
AC 110V 220V 380V 60mm-280mm High Airflow Axial Flow Industrial Fan for Ventilation Exhaust Cooling System

AC 110V 220V 380V 60mm-280mm High Airflow Axial Flow Industrial Fan for Ventilation Exhaust Cooling System

Application industry


Axial fans are used for stable cooling in many different applications and locations.
If the temperature of a device increases, the lives of its internal parts will be reduced and malfunctions could result.
Particularly devices and parts that generate heat are greatly affected by heat.
Device internal cooling and fan selection are extremely important to long-term usage of the parts inside devices.
AC 110V 220V 380V 60mm-280mm High Airflow Axial Flow Industrial Fan for Ventilation Exhaust Cooling System

Remarks

 

Packaging Details        Carton Case or according to your demands
Port                                Shenzhen/hongkong
Lead time                      About 1 weeks after payment confirmed or according to order quantity
After sales service       Warranty is 12 months from shipping date
Packaging picture Example 

AC 110V 220V 380V 60mm-280mm High Airflow Axial Flow Industrial Fan for Ventilation Exhaust Cooling System

Company Profile

AC 110V 220V 380V 60mm-280mm High Airflow Axial Flow Industrial Fan for Ventilation Exhaust Cooling System

 

AC 110V 220V 380V 60mm-280mm High Airflow Axial Flow Industrial Fan for Ventilation Exhaust Cooling System

 

AC 110V 220V 380V 60mm-280mm High Airflow Axial Flow Industrial Fan for Ventilation Exhaust Cooling System

AC 110V 220V 380V 60mm-280mm High Airflow Axial Flow Industrial Fan for Ventilation Exhaust Cooling System

Certifications

 

AC 110V 220V 380V 60mm-280mm High Airflow Axial Flow Industrial Fan for Ventilation Exhaust Cooling System
 

 

Tips


1. When the cooling fan is running, sometimes there is a "da da" collision sound, and sometimes there is no sound.

The reason may be that the dense and messy data cables and power cables in the cooling fan have touched the fan blades of the fan, causing the cooling fan to make abnormal noises when it rotates.

Solution: Use rubber bands, adhesive tape, etc. to bundle the data and power cables inside the half fan, and avoid passing over the cooling fan.

2. The cooling fan was used normally in the early stage, but recently it was suddenly found that the fan automatically moved to a fixed position.

The reason may be that the fastener of the radiator fails, and the fan is displaced due to the resonance phenomenon caused by the rotation of the fan.

Solution: Replace with a new buckle.

3. The cooling fan suddenly makes a loud noise when it is in use, even louder than the sound made by the chassis power supply.

The reason may be that too much dust has accumulated on the surface of the cooling fan and the gaps in the radiator, and the motor lubricating oil of the fan has completely dried up, which causes a motor-like roar.

Solution: We can wipe the cooling fan with soft paper, and use a medical swab to wipe the gaps, then open the plastic sticker off the fan, and drop one to two drops of ordinary sewing machine oil into the movement.

4. If the cooling fan is used for less than a week, there will be excessive noise and poor rotation, but it will return to normal after a period of time.

The reason may be that the indoor temperature where the cooling fan is located is low, which causes the lubricating oil on the rotating bearing to fail.

Solution: Add antifreeze lubricating oil to the cooling fan, pay attention to the temperature of the use environment, and pay attention to its maintenance.

 