• 120X120X38mm 12038 AC120V AC230V AC240V Hot Selling Industrial Ventilation AC Axial Cooling Fan
  • 120X120X38mm 12038 AC120V AC230V AC240V Hot Selling Industrial Ventilation AC Axial Cooling Fan
  • 120X120X38mm 12038 AC120V AC230V AC240V Hot Selling Industrial Ventilation AC Axial Cooling Fan
  • 120X120X38mm 12038 AC120V AC230V AC240V Hot Selling Industrial Ventilation AC Axial Cooling Fan
  • 120X120X38mm 12038 AC120V AC230V AC240V Hot Selling Industrial Ventilation AC Axial Cooling Fan
  • 120X120X38mm 12038 AC120V AC230V AC240V Hot Selling Industrial Ventilation AC Axial Cooling Fan

120X120X38mm 12038 AC120V AC230V AC240V Hot Selling Industrial Ventilation AC Axial Cooling Fan

Certification: RoHS, CE
Rated Voltage: AC220V
Current: 0.14/0.12A
Samples:
US$ 5/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
120X120X38mm 12038 AC120V AC230V AC240V Hot Selling Industrial Ventilation AC Axial Cooling Fan pictures & photos
120X120X38mm 12038 AC120V AC230V AC240V Hot Selling Industrial Ventilation AC Axial Cooling Fan
US $2.5-2.9 / Piece
Min. Order: 1 Piece
Gold Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company
  • Overview
  • Product Parameters
  • Detailed Photos
  • Application industry
  • Remarks
  • Company Profile
  • Certifications
  • Tips
  • Feedback from our clients
Overview

Basic Info.

Model NO.
LX12038HBL
Input Power
20/19W
Fan Bearing
Ball Bearing or Sleeve Bearing
Weight
460g
Transport Package
Carton Packing
Specification
120*120*38mm
Trademark
luckyxin
Origin
China
HS Code
8414599050
Production Capacity
500000pieces/Year

Packaging & Delivery

Package Size
473.00cm * 312.00cm * 379.00cm
Package Gross Weight
20.000kg

Product Description

 

Product Parameters

 
Speed 2850RPM Frame Aluminum
Airflow 90CFM Impeller PBT
Pressure 0.16mmH2O Insulation Class A
Nosie 36dBA Bearing System 2 Ball,Longlife Sleeve
Voltage 220-240v Operation Temperature -10ºC-70ºC
Motora AC  external rotor motor    


Other models:

 AC fan:

 SP100A 1123XSL.GN ,SP100A 1123XST.GN,SP101A 1123HSL.GN ,SP101A 1123HST.GN,SP102A 1123MSL.GN
,SP102A 1123MST.GN ,SP103A 1123LSL.GN ,SP103A 1123LST.GN,SP100A 1123XBL.GN ,SP100A 1123XBT.GN
,SP101A 1123HBL.GN,SP101A 1123HBT.GN,SP102A 1123MBL.GN ,SP102A 1123MBT.GN,SP103A 1123LBL.GN
,SP103A 1123LBT.GN,DP200A 2123XSL.GN ,DP200A 2123XST.GN,DP201A 2123HSL.GN,DP201A 2123HST.GN
,DP202A 2123MSL.GN ,DP202A 2123MST.GN,DP203A 2123LSL.GN,DP203A 2123LST.GN ,DP200A 2123XBL.GN
,DP200A 2123XBT.GN ,DP201A 2123HBL.GN,DP201A 2123HBT.GN ,DP202A 2123MBL.GN ,DP202A 2123MBT.GN
,DP203A 2123LBL.GN ,DP203A 2123LBT.GN,SP109WR 1123HST.GN ,SP109WR 1123HSL.GN,SP109WR 1123HBT.GN
,SP109WR 1123HBL.GN,DP209WR 2123HST.GN,DP209WR 2123HSL.GN,DP209WR 2123HBT.GN,DP209WR 2123HBL.GN, A1123-HST ,A1123-HSL ,A1123-HBT ,A1123-HBL ,A2123-HST ,A2123-HSL ,A2123-HBT ,A2123-HBL
,SF1212AD SL.GN ,SF1212AD BL.GN,DP203A 2123LBL.(5).GN ,DP203A 2123LBT.(5).GN

Detailed Photos

120X120X38mm 12038 AC120V AC230V AC240V Hot Selling Industrial Ventilation AC Axial Cooling Fan
120X120X38mm 12038 AC120V AC230V AC240V Hot Selling Industrial Ventilation AC Axial Cooling Fan

120X120X38mm 12038 AC120V AC230V AC240V Hot Selling Industrial Ventilation AC Axial Cooling Fan

Application industry


Axial fans are used for stable cooling in many different applications and locations.
If the temperature of a device increases, the lives of its internal parts will be reduced and malfunctions could result.
Particularly devices and parts that generate heat are greatly affected by heat.
Device internal cooling and fan selection are extremely important to long-term usage of the parts inside devices.
120X120X38mm 12038 AC120V AC230V AC240V Hot Selling Industrial Ventilation AC Axial Cooling Fan

Remarks

 

Packaging Details        Carton Case or according to your demands
Port                                Shenzhen/hongkong
Lead time                      About 1 weeks after payment confirmed or according to order quantity
After sales service       Warranty is 12 months from shipping date
Packaging picture Example 

120X120X38mm 12038 AC120V AC230V AC240V Hot Selling Industrial Ventilation AC Axial Cooling Fan

Company Profile

120X120X38mm 12038 AC120V AC230V AC240V Hot Selling Industrial Ventilation AC Axial Cooling Fan

 

120X120X38mm 12038 AC120V AC230V AC240V Hot Selling Industrial Ventilation AC Axial Cooling Fan

 

120X120X38mm 12038 AC120V AC230V AC240V Hot Selling Industrial Ventilation AC Axial Cooling Fan

120X120X38mm 12038 AC120V AC230V AC240V Hot Selling Industrial Ventilation AC Axial Cooling Fan

Certifications

 

120X120X38mm 12038 AC120V AC230V AC240V Hot Selling Industrial Ventilation AC Axial Cooling Fan
 

 

Tips


1. When the cooling fan is running, sometimes there is a "da da" collision sound, and sometimes there is no sound.

The reason may be that the dense and messy data cables and power cables in the cooling fan have touched the fan blades of the fan, causing the cooling fan to make abnormal noises when it rotates.

Solution: Use rubber bands, adhesive tape, etc. to bundle the data and power cables inside the half fan, and avoid passing over the cooling fan.

2. The cooling fan was used normally in the early stage, but recently it was suddenly found that the fan automatically moved to a fixed position.

The reason may be that the fastener of the radiator fails, and the fan is displaced due to the resonance phenomenon caused by the rotation of the fan.

Solution: Replace with a new buckle.

3. The cooling fan suddenly makes a loud noise when it is in use, even louder than the sound made by the chassis power supply.

The reason may be that too much dust has accumulated on the surface of the cooling fan and the gaps in the radiator, and the motor lubricating oil of the fan has completely dried up, which causes a motor-like roar.

Solution: We can wipe the cooling fan with soft paper, and use a medical swab to wipe the gaps, then open the plastic sticker off the fan, and drop one to two drops of ordinary sewing machine oil into the movement.

4. If the cooling fan is used for less than a week, there will be excessive noise and poor rotation, but it will return to normal after a period of time.

The reason may be that the indoor temperature where the cooling fan is located is low, which causes the lubricating oil on the rotating bearing to fail.

Solution: Add antifreeze lubricating oil to the cooling fan, pay attention to the temperature of the use environment, and pay attention to its maintenance.

 

Feedback from our clients

120X120X38mm 12038 AC120V AC230V AC240V Hot Selling Industrial Ventilation AC Axial Cooling Fan










 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
120X120X38mm 12038 AC120V AC230V AC240V Hot Selling Industrial Ventilation AC Axial Cooling Fan pictures & photos
120X120X38mm 12038 AC120V AC230V AC240V Hot Selling Industrial Ventilation AC Axial Cooling Fan
US $2.5-2.9 / Piece
Min. Order: 1 Piece
Gold Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company
Registered Capital
1000000 RMB
Plant Area
1001~2000 square meters