60mm Industrial Centrifugal Blower Fan - 24V/12V Mini Turbo Jet Portable Air Blower for Hyundai & HVAC Systems

Product Details
Customization: Available
Material: Plastic
Usage: for Experiment, for Manufacture
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

  • 60mm Industrial Centrifugal Blower Fan - 24V/12V Mini Turbo Jet Portable Air Blower for Hyundai & HVAC Systems
  • 60mm Industrial Centrifugal Blower Fan - 24V/12V Mini Turbo Jet Portable Air Blower for Hyundai & HVAC Systems
  • 60mm Industrial Centrifugal Blower Fan - 24V/12V Mini Turbo Jet Portable Air Blower for Hyundai & HVAC Systems
  • 60mm Industrial Centrifugal Blower Fan - 24V/12V Mini Turbo Jet Portable Air Blower for Hyundai & HVAC Systems
  • 60mm Industrial Centrifugal Blower Fan - 24V/12V Mini Turbo Jet Portable Air Blower for Hyundai & HVAC Systems
  • 60mm Industrial Centrifugal Blower Fan - 24V/12V Mini Turbo Jet Portable Air Blower for Hyundai & HVAC Systems
Find Similar Products
  • Overview
  • Product Parameters
  • Detailed Photos
  • Application industry
  • Remarks
  • Company Profile
  • Certifications
  • Tips
  • Feedback from our clients
Overview

Basic Info.

Model NO.
6025
Flow Direction
Centrifugal
Pressure
Low Pressure
Certification
RoHS, CE
Model
60mm
Rated Voltage
DC24V DC12V
Current
0.08-0.5A
Input Power
0.96-6W
Type
DC Brushless Blower
After-Sales Service Provided
Online Support
Bearing Type
Ball Bearing, Dual Ball Bearing
Transport Package
Carton Packing
Specification
60x60x25mm
Trademark
luckyxin
Origin
China
HS Code
8414599050
Production Capacity
1000000pieces/Year

Product Description

 

 

Product Parameters

  
Speed 3000-6000rpm Frame PBT
Airflow 7-14CFM Impeller PBT
Pressure 10-39mmAq Insulation Class A
Nosie 33-45dBA Bearing System 2 Ball,Longlife Sleeve, FDB
Voltage DC12v DC24V  Operation Temperature -10ºC-70ºC
Motor DC brushless external rotor motor    

Above Specification is only for reference, please contact us for more details.
 

12V 60mm High Performance 6025 Axial Blower 2 Inch DC Fan Blower 24V 60X60X25

DC Blower fan 60mm x 60mm x 25mm 6025 DC 5V 12V 24V Mini Blower Fan


50mm 5015 Blower Fan 5V, 3D Printer 5 Volt Fans Blower Turbine Turbo Dual Ball Bearing, Brushless Cooling 50mmx15mm 2PIN
120mm x 32mm 12V High Airflow DC Brushless Blower Fan for Radiator, Desktops, Gaming Consoles, TVs, Routers, Computers

 

DC 97mm Blower Fan 12V 9733 Dual Ball Bearing Brushless Cooling Turbine Turbo 97x33mm 2PIN

 

3wires 50x50x15mm DC Fans DC 5V Cool Blower Fan 5015  Hotend Cooler  Fan for 3D Printer

 

12V DC Blower Fan 120mm x 32mm 4.72inch 2Pin High Airflow Brushless Exhaust Fan Blower for  More 3000RPM

 

DC Centrifugal Fan 12V 75mm x 30mm Brushless Cooling Turbo Blower Fan 3 inch

 

120mm DC Small Blower Fan High Speed 12032 3700RPM with Stepless Speed Controller 1800-3700 RPM for  DIY Cooling Ventilation Exhaust Projects

Brushless Radial Blower Fan High Speed 24V DC Centrifugal Fan 120mm x120mm x 32mm

 

Blower Fan DC 12V 2W 0.18A,Length 1.97 Inch Height 1.97 Inch Thichness 0.59 Inch  Frame DC Brushless Fan,5000 RPM DC Cooling Fan,2.5-2P pin


60mm centrifugal fan

industrial blower fan

220v blower fan

12v blower fan

turbo jet blower   60mm mini blower

small centrifugal fan

compact blower fan   dual voltage blower

220v centrifugal fan

12v industrial fan   portable air blower

high airflow blower

turbo cooling fan

brushless blower fan    HVAC blower fan







60mm Industrial Centrifugal Blower Fan - 24V/12V Mini Turbo Jet Portable Air Blower for Hyundai & HVAC Systems



 

 

Detailed Photos

60mm Industrial Centrifugal Blower Fan - 24V/12V Mini Turbo Jet Portable Air Blower for Hyundai & HVAC Systems
60mm Industrial Centrifugal Blower Fan - 24V/12V Mini Turbo Jet Portable Air Blower for Hyundai & HVAC Systems

60mm Industrial Centrifugal Blower Fan - 24V/12V Mini Turbo Jet Portable Air Blower for Hyundai & HVAC Systems

Application industry


Axial fans are used for stable cooling in many different applications and locations.
If the temperature of a device increases, the lives of its internal parts will be reduced and malfunctions could result.
Particularly devices and parts that generate heat are greatly affected by heat.
Device internal cooling and fan selection are extremely important to long-term usage of the parts inside devices.
60mm Industrial Centrifugal Blower Fan - 24V/12V Mini Turbo Jet Portable Air Blower for Hyundai & HVAC Systems

Remarks

 

Packaging Details        Carton Case or according to your demands
Port                                Shenzhen/hongkong
Lead time                      About 1 weeks after payment confirmed or according to order quantity
After sales service       Warranty is 12 months from shipping date
Packaging picture Example 

60mm Industrial Centrifugal Blower Fan - 24V/12V Mini Turbo Jet Portable Air Blower for Hyundai & HVAC Systems

Company Profile

60mm Industrial Centrifugal Blower Fan - 24V/12V Mini Turbo Jet Portable Air Blower for Hyundai & HVAC Systems

 

60mm Industrial Centrifugal Blower Fan - 24V/12V Mini Turbo Jet Portable Air Blower for Hyundai & HVAC Systems

 

60mm Industrial Centrifugal Blower Fan - 24V/12V Mini Turbo Jet Portable Air Blower for Hyundai & HVAC Systems

60mm Industrial Centrifugal Blower Fan - 24V/12V Mini Turbo Jet Portable Air Blower for Hyundai & HVAC Systems

Certifications

 

60mm Industrial Centrifugal Blower Fan - 24V/12V Mini Turbo Jet Portable Air Blower for Hyundai & HVAC Systems
 

 

Tips


1. When the cooling fan is running, sometimes there is a "da da" collision sound, and sometimes there is no sound.

The reason may be that the dense and messy data cables and power cables in the cooling fan have touched the fan blades of the fan, causing the cooling fan to make abnormal noises when it rotates.

Solution: Use rubber bands, adhesive tape, etc. to bundle the data and power cables inside the half fan, and avoid passing over the cooling fan.

2. The cooling fan was used normally in the early stage, but recently it was suddenly found that the fan automatically moved to a fixed position.

The reason may be that the fastener of the radiator fails, and the fan is displaced due to the resonance phenomenon caused by the rotation of the fan.

Solution: Replace with a new buckle.

3. The cooling fan suddenly makes a loud noise when it is in use, even louder than the sound made by the chassis power supply.

The reason may be that too much dust has accumulated on the surface of the cooling fan and the gaps in the radiator, and the motor lubricating oil of the fan has completely dried up, which causes a motor-like roar.

Solution: We can wipe the cooling fan with soft paper, and use a medical swab to wipe the gaps, then open the plastic sticker off the fan, and drop one to two drops of ordinary sewing machine oil into the movement.

4. If the cooling fan is used for less than a week, there will be excessive noise and poor rotation, but it will return to normal after a period of time.

The reason may be that the indoor temperature where the cooling fan is located is low, which causes the lubricating oil on the rotating bearing to fail.

Solution: Add antifreeze lubricating oil to the cooling fan, pay attention to the temperature of the use environment, and pay attention to its maintenance.

 

Feedback from our clients

60mm Industrial Centrifugal Blower Fan - 24V/12V Mini Turbo Jet Portable Air Blower for Hyundai & HVAC Systems



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier