AC230V AC220V DC/Ec Forward Curved Brushless Centrifugal Exhaust Fan Swq160he2 for Industrial Cooling Blower Fans

Product Details
Customization: Available
Material: Aluminum
Usage: for Experiment, for Air Conditioner, for Manufacture, for Refrigerate
Still deciding? Get samples of US$ 50/Piece
Request Sample
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • AC230V AC220V DC/Ec Forward Curved Brushless Centrifugal Exhaust Fan Swq160he2 for Industrial Cooling Blower Fans
  • AC230V AC220V DC/Ec Forward Curved Brushless Centrifugal Exhaust Fan Swq160he2 for Industrial Cooling Blower Fans
  • AC230V AC220V DC/Ec Forward Curved Brushless Centrifugal Exhaust Fan Swq160he2 for Industrial Cooling Blower Fans
  • AC230V AC220V DC/Ec Forward Curved Brushless Centrifugal Exhaust Fan Swq160he2 for Industrial Cooling Blower Fans
  • AC230V AC220V DC/Ec Forward Curved Brushless Centrifugal Exhaust Fan Swq160he2 for Industrial Cooling Blower Fans
  • AC230V AC220V DC/Ec Forward Curved Brushless Centrifugal Exhaust Fan Swq160he2 for Industrial Cooling Blower Fans
Find Similar Products
  • Overview
  • Product Parameters
  • Detailed Photos
  • Application industry
  • Remarks
  • Company Profile
  • Certifications
  • Tips
  • Feedback from our clients
Overview

Basic Info.

Model NO.
SWQ160HE2
Flow Direction
Centrifugal
Pressure
Low Pressure
Certification
RoHS, CE
Rated Voltage
AC220V
Current
0.34A
Input Power
85W
Speed
2250rpm
Noise
65dB
Weight
3.2kg
Transport Package
Carton Packing
Specification
227*100mm
Trademark
luckyxin
Origin
China
HS Code
8414599050
Production Capacity
100000pieces/Year

Product Description

 
 

Product Parameters

 
Speed 2250RPM Frame PBT
Airflow 700M3/H Impeller PBT
Pressure 790pa Insulation Class A
Nosie 65dBA Bearing System 2 Ball,Longlife Sleeve, FDB
Voltage 220-240v Operation Temperature -10ºC-70ºC
Motor AC brushless external rotor motor    

 Above Specification is only for reference, please contact us for more details.

Other models:

EC Centrifugal FAN Made in China:
SG133HE2,SG146HE2,SW133HE2,SW175HE2,SW190HE2(72),SW190HE2(92),SW220HE2(72),SW220HE2(92),SW225HE2(72),SW225HE2(92),SW250HE2,SW280HE2(92),SW310HE2,SW400HE2,SWQ108HE2,SWQ120HE2,SWQ133HE2,SWQ140HE2(72),SWQ160HE2,SWQ180HE2(92)


AC230V AC220V DC/Ec Forward Curved Brushless Centrifugal Exhaust Fan Swq160he2 for Industrial Cooling Blower Fans

Detailed Photos

AC230V AC220V DC/Ec Forward Curved Brushless Centrifugal Exhaust Fan Swq160he2 for Industrial Cooling Blower Fans
AC230V AC220V DC/Ec Forward Curved Brushless Centrifugal Exhaust Fan Swq160he2 for Industrial Cooling Blower Fans

AC230V AC220V DC/Ec Forward Curved Brushless Centrifugal Exhaust Fan Swq160he2 for Industrial Cooling Blower Fans

Application industry


Axial fans are used for stable cooling in many different applications and locations.
If the temperature of a device increases, the lives of its internal parts will be reduced and malfunctions could result.
Particularly devices and parts that generate heat are greatly affected by heat.
Device internal cooling and fan selection are extremely important to long-term usage of the parts inside devices.
AC230V AC220V DC/Ec Forward Curved Brushless Centrifugal Exhaust Fan Swq160he2 for Industrial Cooling Blower Fans

Remarks

 

Packaging Details        Carton Case or according to your demands
Port                                Shenzhen/hongkong
Lead time                      About 1 weeks after payment confirmed or according to order quantity
After sales service       Warranty is 12 months from shipping date
Packaging picture Example 

AC230V AC220V DC/Ec Forward Curved Brushless Centrifugal Exhaust Fan Swq160he2 for Industrial Cooling Blower Fans

Company Profile

AC230V AC220V DC/Ec Forward Curved Brushless Centrifugal Exhaust Fan Swq160he2 for Industrial Cooling Blower Fans

 

AC230V AC220V DC/Ec Forward Curved Brushless Centrifugal Exhaust Fan Swq160he2 for Industrial Cooling Blower Fans

 

AC230V AC220V DC/Ec Forward Curved Brushless Centrifugal Exhaust Fan Swq160he2 for Industrial Cooling Blower Fans

AC230V AC220V DC/Ec Forward Curved Brushless Centrifugal Exhaust Fan Swq160he2 for Industrial Cooling Blower Fans

Certifications

 

AC230V AC220V DC/Ec Forward Curved Brushless Centrifugal Exhaust Fan Swq160he2 for Industrial Cooling Blower Fans
 

 

Tips


1. When the cooling fan is running, sometimes there is a "da da" collision sound, and sometimes there is no sound.

The reason may be that the dense and messy data cables and power cables in the cooling fan have touched the fan blades of the fan, causing the cooling fan to make abnormal noises when it rotates.

Solution: Use rubber bands, adhesive tape, etc. to bundle the data and power cables inside the half fan, and avoid passing over the cooling fan.

2. The cooling fan was used normally in the early stage, but recently it was suddenly found that the fan automatically moved to a fixed position.

The reason may be that the fastener of the radiator fails, and the fan is displaced due to the resonance phenomenon caused by the rotation of the fan.

Solution: Replace with a new buckle.

3. The cooling fan suddenly makes a loud noise when it is in use, even louder than the sound made by the chassis power supply.

The reason may be that too much dust has accumulated on the surface of the cooling fan and the gaps in the radiator, and the motor lubricating oil of the fan has completely dried up, which causes a motor-like roar.

Solution: We can wipe the cooling fan with soft paper, and use a medical swab to wipe the gaps, then open the plastic sticker off the fan, and drop one to two drops of ordinary sewing machine oil into the movement.

4. If the cooling fan is used for less than a week, there will be excessive noise and poor rotation, but it will return to normal after a period of time.

The reason may be that the indoor temperature where the cooling fan is located is low, which causes the lubricating oil on the rotating bearing to fail.

Solution: Add antifreeze lubricating oil to the cooling fan, pay attention to the temperature of the use environment, and pay attention to its maintenance.

 

Feedback from our clients

AC230V AC220V DC/Ec Forward Curved Brushless Centrifugal Exhaust Fan Swq160he2 for Industrial Cooling Blower Fans



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier